크로마토그래피 원리의 큰 틀도 마찬가지로 두 상에 대한 분배 차이를 이용하여 분석물을 분리, 정제할 수 있습니다. 다만 크로마토그래피에서 두 개의 상은 하나는 고정하고 다른 하나는 일정 방향으로 이동시켜 사용합니다.
If we switch from applying acetonitrile to tetrahydrofuran, one example is, we notice that benzoic acid elutes a lot more swiftly Which p
The solvent reservoir holds the cell stage, a liquid or solvent combination that continuously flows throughout the HPLC system. The cell section plays a crucial part in separating sample components.
Compatibility: The solvent should not respond Along with the analytes or degrade the sample matrix. Consult safety data sheets (SDS) for compatibility facts.
Inside the column, separation happens depending on the differential interactions among analytes along with the stationary stage. Analytes using a much better affinity for that stationary section go slower with the column compared to These with weaker interactions.
シリカゲルの粒子径が小さければ小さいほどピークの分離性は良くなるが、送液に必要なポンプの圧力が高くなる。そのため、ポンプ-インジェクター間、インジェクター-カラム間の配管の耐圧を上げたり、カラム自体を比較的高温の下にさらして溶媒の粘度を下げ、抵抗を小さくする工夫をしている。
규제 약물(마약, 합성 마약, 대마, 각성제, 향정신성 의약품, 아편양제제 등), 반도핑 관련(금지 물질, 금지 약물, 스테로이드 등), 약물 대사물
前述した従来の順相タイプに対して、逆相クロマトグラフィーにおいては固定相に低極性のもの(例えばシリカゲルにアルキル基を共有結合させたもの)を、移動相に高極性のもの(例えば水や塩類の水溶液、アルコール、アセトニトリルなどの有機溶媒)を用いる。また珍しいケースではあるが、分離のための移動相pHをシリカゲルの使用範囲から外れたところに設定する必要がある場合、あるいはシリカゲル表面に残っている未反応シラノール基が分離に悪影響を及ぼし、かつそれが移動相の変更によっても解決できない場合には、固定相として樹脂を用いることがある。分析物はより極性の低いほどより強く固定相と相互作用して溶出が遅くなる。また極性の低い物質の割合が多い移動相ほど溶出が早くなる。
Weak resolution signifies analytes elute way too close alongside one another, building them challenging to distinguish. Here is the best way to troubleshoot:
). As the tubing and fittings that carry the cellular phase have strain limitations, a higher again strain requires a lessen flow fee and an extended Investigation time. Monolithic columns, where the reliable support is one, porous rod, supply column efficiencies comparable to a packed capillary column although letting for faster flow fees. A monolithic column—which ordinarily is similar in measurement to a standard packed column, Even though scaled-down, capillary columns also are offered—is prepared by forming the mono- lithic rod within a mold and masking it with PTFE tubing or simply a polymer resin.
When the mobile section’s pH is sufficiently acidic, the solutes are current as neutral weak acids which are additional soluble within the stationary section and consider website extended to elute. Since the weak acid solutes do not have identical p
There are numerous choices for checking the chromatogram when using a mass spectrometer as the detector. The commonest process is to repeatedly scan the entire mass spectrum and report the entire signal for all ions achieving the detector all through Just about every scan. This total ion scan provides common detection for all analytes. As observed in Figure 12.five.14
Mobile section impurities: Contaminants in the cell stage can elute from the column and show up as ghost peaks. Put together a refreshing cell stage with high-purity solvents and think about filtering the cell phase right before use.
An inner regular is essential when working with HPLC–MS more info because the interface between the HPLC as well as mass spectrometer isn't going to allow for for any reproducible transfer of your column’s eluent into the MS’s ionization chamber.